AS/NZS 3000-2018

Australia's MEN Earthing System

Australia uses the Multiple Earthed Neutral (MEN) system — equivalent to TN-C-S in IEC terminology. In this system, the supply neutral is earthed at the transformer, along the distribution line, and again at the customer's main switchboard (the MEN link). This means the earth and neutral conductors share impedance in the distribution network, but are separate inside the customer's installation.

What This Means for Solar Earthing

Component

Earthing Requirement

Connection Point

Inverter chassis

Connected to main earth bar via dedicated PE conductor

Main switchboard earth bar

Panel frames

Bonded to mounting rail via manufacturer's bonding provisions

Rail to roof frame to earth stake or to structure earth

Mounting rail

Bonded to structure earth or to the inverter PE conductor

One bond point per 20 m of rail length

DC conduit (metallic)

Connected to PE system

At each junction box and at inverter end

Battery enclosure (metal)

Connected to PE system

Main earth bar

Transformerless Inverter Earthing — The Critical Rule

In a transformerless inverter (the most common residential type), the DC and AC circuits share a common reference through the inverter's internal capacitances. The inverter's GFD function monitors this shared reference. If an installer adds an external earth bond on the DC negative conductor (thinking this makes the system safer), it actually:

  • Creates a reference point that prevents the GFD from detecting a ground fault on the DC negative conductor

  • May cause nuisance tripping or GFD bypass conditions

  • Creates an earth loop that allows fault current to flow through panel frames

Rule: Never add an external earth bond on the DC positive or negative conductor of a transformerless inverter. The inverter manufacturer's earthing diagram must be followed exactly.

Engr. Jason Morales — Founder, SolarEnergyPH

Installation and safety requirements for PV arrays (AS 5033-2014) & Guide to solar safe installation
Installation and safety requirements for PV arrays (AS 5033-2014) & Guide to solar safe installation
A two-in-one reference covering PV array installation and safety requirements per AS 5033-2014, bundled with a practical safe solar installation guide — essential reading for solar installers, elec...